HANDLING/ASSEMBLY/INSTALLING
HANDLING: Always lift the
unit from the bottom. Never try to lift by the top plate. While on the
pallet, use a pallet jack or lift truck to move. After removing from
pallet, a two- wheeler may be used on the side of the unit opposite the
manifold cover box, left side facing the front of the unit.

INSTALLING: Place the unit three feet from existing
buildings or obstructions. Do Not put unit in any enclosure (leave
outside).
Pick a good location for your heater.
DO NOT install in any enclosure, unit must stay outside.
Recommendations:
-
Any place close to your pump/filter
is the best.
-
Heater needs to sit on a concrete or
brick foundation. 36" square or larger.
-
Can be installed as close as 2-3
feet from your pool pump and filter, without causing a heat problem.
-
Can be installed next to the house.
Check with all local codes before doing this type of install. Be careful
that no sparks or embers are coming out of the chimney. If you see any
with your first burn, get a spark arrestor on the pipe before burning
again.
-
Can be installed up to 20-30 feet
away from your pump, by running the water pipes underground to & from
the heater.
This allows you to have your heater
in a separate area of the yard, insulating those pipes will help to prevent heat
loss underground.

Multiple installation example
ASSEMBLY: Inside the unit, you will find a 24" piece of 6"
stove pipe with crimping on both ends. One end of the pipe has a small
ring at the end of the crimping. Install this end in the stove, put the
cap on the other end and position the temperature indicator
approximately halfway up the pipe.
PLUMBING & WINTERIZING
PLUMBING: The unit has two
positions labeled INLET & OUTLET. These are 1-1/2" schedule 40 PVC Pipe
"Glue type Fittings". Cut into the pool’s return line after it leaves
the filter and run pipe to Inlet position. Then, run pipe from Outlet
position back to remaining segment of pool’s return line.
We recommend that you install on 1-1/2" PVC Tee. If you use a tee in
this position, it will make it easier to winterize the unit. Install a
drain plug in the bottom of each tee & simply remove these plugs to
winterize. (see winterize instructions below) You may experience
back-pressure on your pressure gauge at the filter after installing the
unit. If so, installation of a bypass line and valve will eliminate the
problem. If this is necessary, open the valve just enough to relieve the
back-pressure.
The wood heater is designed to be plumbed into your existing pool water
piping and equipment. Always install any automatic chlorination device
AFTER the wood heater, so that you never send pool chemicals directly
into the heater.
WINTERIZE: Remove drain plugs on bottom of the Tees at the
Inlet and Outlet positions, blow compressed air into the outlet position
tee until all water quits coming out of inlet position tee.
For more product information or general questions
about our Hydro-Stove Wood Heaters please call us at:
1 800 741 9956
You can also email us at:
info@thermal-bay.com
|
We try to offer the lowest price on the Internet. We will try to match any competitors price
after delivery and taxes, don't feel shy about asking. Buying from us should be the
friendliest, most painless, cost effective buying experience anywhere. This is
our commitment to you. |
Thermal Bay Technologies is an
exclusive national distributor for Hydro-Stove Wood Heaters manufactured by
Roger's Machine Company in Arkansas.
Proudly made in the USA.

Thermal Bay
Technologies
1740 H dell Range Blvd. #4946
Cheyenne, WY 82009-4946
|